2000 Rod Pump Controller Approvals
- FCC Part 15, Subpart B, Class A Digital Device
- EU EMC Directive 89/336/EEC
- CSA approved Industrial Control Equipment–Motor Controller–Miscellaneous
Expansion I/O Boards for the 2000 Rod Pump Controller
Board
Number |
Analog
Inputs |
Digital
Inputs |
Digital
Outputs |
Analog
Outputs |
| 1 |
2 |
2 |
2 |
0 |
| 2 |
4 |
4 |
4 |
0 |
| 3 |
8 |
4 |
4* |
0 |
| * Can be configured as DI or DO |
2000 Rod Pump Controller Specifications
| Rod Pump Controller |
| Enclosure |
NEMA 4X |
| Weight |
Approximately 22 pounds |
| Input voltage range |
480-Vac,120/240-Vac, 12-Vdc |
| Frequency |
47- to 63-Hz |
| Relay output |
Control and watchdog |
| Operating temperature |
-40° to +185°F (-40° to +85°C) |
| Printed circuit boards |
Conformally coated to protect against moisture, H2S, and salt air |
| Communication protocol |
Operator selectable, 8500 native, Modbus RTU, or Modbus ASCII |
| Transient Protection |
| Overvoltage/transient |
Meets ANSI/IEEE C37.90.1-2989 protection specifications |
| Dynamometer card resolution |
Samples and stores load and position data at 20 times-per-second for down-hole analysis |
| Pump-off or reverse pump-off Detection |
Setpoint or quadrant method |
| Analog-to-digital conversion |
Monolithic, successive approximation 12-bit A/D converter |
| Polished Rod Load Cell |
| Class |
Quantitative strain gauge |
| Range |
0- to 30,000-lb. or 0- to 50,000-lb. |
| Maximum error |
±0.5% |
| Operating temperature |
-70° to +190°F (-55° to +88°C) |
|
 |
|
|