SEARCH     
 

Subsea Control Module Design Criteria

Environmental Data
Water Depth 3000 meters LAT
Operating temperature range (°F/°C) Surface unit = 23 to 104 (-5 to 40)
Subsea unit = 23 to 104 (-5 to 40)
Shock iaw ISO 13628-6
Vibration iaw ISO 13628-6
EMC iaw ISO 13628-6

Subsea Equipment Design
Design life 25 years
Intervention ROV or diver deployment and intervention
SCM size (in./mm)
33.5 x 33.5 x 3 high (850 x 850 x 75 high), excluding mounting base
SCM weight (lb./kg)
In air, 1874 (850)
In water, 1323 (600) approximately
SCM housing Pressure compensated, dielectric fluid filled
Mounting Subsea tree or manifold structure (ROV to API 17 H or diver)

System Pressures & Fluid
High pressure (psig/barG) 15k (1034) MWP
Low pressure (psig/barG) 5k (345) MWP
Control fluid Water based biodegradable, open loop or petroleum based synthetic mineral oil (standard)
Control fluid cleanliness NAS 1638 Class 6
Supply filtration Integral single B3–200 rating elements (3 micron)

Electrical
Analog 4 to 20 mA (standard) 12-bit, other configurations available
Discrete 24 VDC, 0.5 to 8 A (maximum) output configurable
24 VDC input configuration available
Power supply 110, 230 or 480, 50/60 Hz single phase (nominal), 24 VDC (option)
Communications Comms-on-power, comms-and-power and/or fiber optic
© 2012 Weatherford International Ltd.