SEARCH     
 

Specifications of the Red Eye® Multiphase Water-Cut Meter

Power 10 to 30 Vdc, 8 W
Wetted parts 316 L SS or Hastelloy C 276 with sapphire windows
Operating temperature (°F/°C) 32 to 302 (0 to 150) (standard) process fluid
  -40 to 149 (-40 to 65) (standard) ambient temp
Operating pressure Equal to carbon steel ANSI pressure rating
Process connection (in./cm) 1 (2.54) NPT for pipe sizes 2 to 10 (5.08 to 25.4)
  1.5 (3.81) RF flange ANSI 600 for pipe sizes 2 to 24 (5.08 to 60.96)
  1.5 (3.81) RF flange ANSI 900/1500 for pipe sizes 2 to 24 (5.08 to 60.96)
  2 (5.08) RTJ flange ANSI 900/1500 for pipe sizes 3 to 8 (7.62 to 20.32)
Sour service NACE MR0175/ISO 15156
Accuracy Refer to plot
Communication ports RS232 and RS485
Display 2-line, 16-character vacuum fluorescent display (LCD available)
Output 4 to 20 mA water cut
Communications Modbus® RTU (standard)
Hazardous Area
Classification (pending)
Factory Mutual Approvals Project I.D. 3022805 XP Class I, Division 1, Groups C & D, T3C, Ta=+85°C, CSA
  Sira Certification Services Certificate SIRA 05ATEX1138 EEx’d IIB T3 Ta=+85°C, IP66
  Canadian Standards Association Certificate Number 1675737, Class I, Division 1, Groups C & D, T3C, Ta=+85°C, Type 4
  Serial Production Gosstandart of Russia Certificate of Conformity
  Gosstandart of Russia Explosion-proof Certificate
Hot tap A hot tap version of the Red Eye multiphase water-cut meter is available, contact the factory for details
© 2010 Weatherford International Ltd.