SEARCH     
 

Specifications of the ePAC™ Electric Submersible Pump (ESP) System

Electrical Input Supply
Voltage 380- to 480-Vac (±10%)
Frequency 47- to 63-Hz

Electrical Power Factor
Overall 0.00 to 0.94 depending on speed for six-step outputs
0.94 at all speeds for pulse width modulated outputs
0.99 at all speeds with harmonic eliminator

Electrical Output Rating
Voltage Zero to input voltage, three-phase
Frequency 0- to 120-Hz flux vector control
0- to 300-Hz variable frequency control
Switching frequency Programmable, 2- to 12-kHz
Overload current Constant torque: 150% of rated for 1 minute, maximum of 200% rated
Variable torque 120% of rated for 1 minute, maximum of 140% to 160% of rated
Extended torque 110% of rated for 1 minute, maximum of 120% to 140% of rated

Electrical Conversion
Rectifier unit Six-SCR, three-phase (6-pulse) full-wave bridge rectification
Inverter unit Six-IGBT, four-quadrant, six-step, trapezoidal or sinusoidal output

Environmental
Operating temperature 32° to 122°F (0° to 50°C)
Storage temperature 5° to 158°F (-15° to 70°C)
Relative humidity 5% to 95%, non condensing
Altitude 0 to 3,300 ft. (1,000 m) at full rating

Inputs and Outputs
Analog inputs Three 12 bit analog inputs (±10 Vdc or 4- to 20-mA)
Analog outputs Two 12 bit analog outputs (±10 Vdc and 4- to 20-mA)
Digital inputs 12 digital inputs (requires sink of 1 mA to common)
Digital Outputs Six digital outputs (open-collector drivers rated 24 Vdc @ 500 mA)

Serial Communications
Asynchronous port EIA RS-232 and RS-422/485, isolated, 0.3- to 19.2-kbaud
ANSI-x3.28-2.5-A4, Allen-Bradley
DF1 and Modicon RTU protocols
Synchronous port EIA RS-485 for high-speed master/slave networking
© 2010 Weatherford International Ltd.