SEARCH     
 

Specifications of the ePAC™ Progressive Cavity Pumping (PCP) System

Electrical Input Supply
Voltage 230, 380, 460, or 575 Vac (±10%)
Frequency 47- to 63-Hz

Electrical Power Factor
Overall 1.00 displacement power factor
0.94 overall power factor at all speeds

Electrical Output Rating
Voltage Zero to input voltage, three-phase
Frequency Zero to 120 Hz flux vector control
Zero to 300 Hz variable frequency control
Switching frequency Programmable, 2 to 12 kHz
Overload current Constant torque: 150% of rated for 1 minute, maximum of 200% rated
Variable torque 120% of rated for 1 minute, maximum of 140% to 160% of rated
Extended torque 110% of rated for 1 minute, maximum of 120% to 140% of rated

Electrical Conversion
Rectifier unit 6-diode, 3-phase (6-pulse) full wave bridge below 60-Hp
Diode-SCR, 6-phase (12-pulse) full-wave bridge for 60-Hp and above
Inverter unit 6-IGBT, 4-quadrant, trap or sine wave output

Environmental
Operating temperature 32° to 122°F (0° to 50°C)
Storage temperature 5° to 158°F (-15° to 70°C)
Relative humidity 5% to 95%, non condensing
Altitude 0- to 3,300-ft. (1,000 m) at full rating

Inputs and Outputs
Analog inputs Three 12 bit analog inputs (±10 Vdc or 4 to 20 mA)
Analog outputs Two 12 bit analog outputs (±10 Vdc and 4 to 20 mA)
Digital inputs 12 digital inputs (requires sink of 1 mA to common)
Digital outputs Six digital outputs (open-collector drivers rated 24 Vdc @ 500 mA)

Serial Communications
Asynchronous port EIA RS-232 and RS-422/485, isolated, 0.3- to 19.2‑kbaud
ANSI-x3.28-2.5-A4, Allen-Bradley DF1, and Modicon RTU protocols
Synchronous port EIA RS-485 for high-speed master/slave networking
© 2010 Weatherford International Ltd.