SEARCH     
 

Specifications of the ePIC™ Rod Pump Controller

Rod Pump Controller
Enclosure NEMA 4
Weight Approximately 22 pounds
Input voltage range 120/240 Vac or 12 to 24 Vdc
Frequency 47 to 63 Hz
Relay output 12 Vdc
Operating temperature -40° to +185°F (-40° to +85°C)
Printed circuit boards Conformally coated to protect against moisture, H2S, and salt air
Communication protocol Operator selectable, CAC 8500 native, Modbus™ RTU, or Modbus ASCII

Transient Protection
Overvoltage/transient Meets ANSI/IEEE C37.90.1-2989 protection specifications
Dynamometer card resolution Samples and stores load and position data at 20 times-per-second for downhole analysis
Analog-to-digital conversion Monolithic, successive approximation 12-bit A/D converter

Clamp on Beam Load Transducer (Beam Sensor)
Operating Temperature -60° to +212°F
Temperature Effect on Zero ±0.19uV°F
Temperature Effect on Output ±0.0008% of full scale/°F
Combined Accuracy 0.5% to 1.0% full scale

DPS (Dual Position Sensor)
Analog output 0 to 5 Volts
Tilt Range ±45° to ±22°
Accuracy 0.1 degree of tilt
Filters Four selectable digital filters
Input voltage 8 to 15 Vdc @ 14 mA

Polished Rod Load Cell
Class Quantitative strain gauge
Range 0- to 30,000 lb. or 0 to 50,000 lb.
Maximum error ±0.5% full scale
Operating temperature -70° to +190°F (-55° to +88°C)


ePIC
Rod Pump Controller Expansion I/O Boards

Board
Number
Analog
Inputs
Digital
Inputs
Digital
Outputs
Analog
Outputs
1 2 2 2 0
2 4 4 4 0
3 8 4 4* 1

*Can be configured as DI or DO

© 2010 Weatherford International Ltd.