sPOD™ Single Point Digital Gauge - Pressure/Temperature

Quick Links to Information Below

PDF Documents

Overview of the sPOD Single Point Digital Gauge

Weatherford’s production optimization group, eProduction Solutions (eP), offers the sPOD single point digital gauge. This instrument is ideal when a single pressure/temperature (P/T) gauge is to be installed in any completion. The basics of design allow the transducer to convert an applied pressure into a change of resistance. The strain of the applied pressure is measured across an active four wire resistive bridge and the temperature is measured from a secondary of the main bridge.

The purpose of the temperature measurement is so that the pressure transducer output can compensate for temperature induced errors (“temperature compensated” for increased pressure accuracy over a broad temperature range).

The gauge is designed specifically to address the demanding environment encountered in permanent monitoring applications. eP’s design incorporates minimal electronics, this decreases infant mortality commonly experienced in other gauge designs.

sPOD gauge usage includes all permanent applications where pressure and temperature data is needed for monitoring, optimization, analysis or control purposes.

sPOD Single Point Digital Gauge Solutions


Casing Sensing TD-PGC Adapter Sensor


Tubing Sensing TD-PGC Adapter Sensor


Casing or Tubing SSM Adapter Sensor

Specifications of the sPOD Single Point Digital Gauge

Temperature

Gauge Type

Integral to pressure

Range

59° to 257°F (15° to 125°C)

Accuracy

±1.8°F

Resolution

0.1°F

Pressure

Gauge Type

Piezo resistive, silicon-on-insulator (SOI)

Range

0- to 3000-PSI (0- to 206.8-BAR), 0- to 5000-PSI (0- to 344.7-BAR), 0- to 7,500-PSI (0- to 517.1-BAR)

Accuracy

0.10% FS (typically 0.07% FS)

Resolution

0.01% FS

Vibration

Force of Acceleration (G)

Continuous at 40 G, peak at 100 G (continuous at 5394 cm/sec2, peak at 7355 cm/sec2)

Shock

2.204 lbs. Force (1 kg. Force), all axis

Frequency

Maximum 2 KHz

General

Drift

<6 PSI/YR (<0.4 BAR/YR), typically <2 PSI/YR (<0.1 BAR/YR)

Cable Length

Unlimited (compliance test @ 20,000 ft.)

Power Consumption

11 mA @ 15 Vdc

Material

Transducer Body and Isolation Diaphragm

Hastalloy C276™

Pressure Housing, Cable Adapter and Union

Stainless steel (optional: Inconel 925™, Hastalloy C276™)