Clarion™ Optical Seismic Instrumentation Specifications
| System Performance |
| Bandwidth |
1 Hz to 1.4 kHz |
| Number of optical channels |
Up to 32, 8 per fiber |
| Number of analog input auxiliary channels |
4 |
| Dynamic range |
129 dB at 10Hz, 1mS sampling (digital output) |
| Distortion |
0.1% (–60 dB) typical |
| Interchannel crossfeed |
1% (–40 dB) typical |
| Noise-equivalent acceleration |
200nG rms / √Hz typical, 10Hz to max BW |
| Analog data output |
Continuous differential or single-ended |
| Analog output sensitivity |
Scalable from instrument |
| Accelerometer |
0.2 to 200 V/G |
| Digital data output |
| Data format |
SEG-2 with optional P/T data combined |
| Sample interval |
1/4, 1/2, 1 and 2 mS |
| Maximum record length* |
197 sec at 1mS sampling, 16 ch |
| |
113 sec at 1/2 mS sampling, 8 ch |
| Maximum wellpath length |
19,686 ft (6,000 m) typical |
| Maximum offset to wellhead |
18.6 mi (30 km) typical without amplification |
*Dependent on number of channels and sample interval
| Instrumentation |
| Standard configurations |
19-in. (483-mm) rack-mount portable enclosures or fixed cabinet |
| Optional features |
UPS, mass storage, remote access via modem or Ethernet LAN/WAN, direct interface to Weatherford Reservoir Monitoring system P/T data, GPS synchronization |
| Power |
<600 W at 100 to 240 VAC, 50 to 60 Hz, single phase |
| Operating temperature (°F/°C) |
32 to 104
0 to 40 |
| Storage temperature (°F/°C) |
–4 to 158
–20 to 70 |
| Space Requirements* |
| Height (in./cm) |
57.9
147 |
| Width (in./cm) |
21.3
54 |
| Depth (in./cm) |
34.3
87 |
| Weight (lb/kg) |
320
145 |
*As packaged in 19-in. rack-mount, fixed cabinet
Overview
Clarion Optical Seismic Accelerometer
Specifications of the Optical Seismic Accelerometer
Clarion Optical Seismic Instrumentation
Specifications of the Optical Seismic Instrumentation
Clarion Seismic Sensing Station and Deployment System