SEARCH     
 
Optimization Systems

Optical-Sensor Reservoir Monitoring System RMS and RMS-MR Models Specifications

Cabinet Specifications
Standard Cabinet Sizes Weight (lb/kg) Overall Dimensions
(in./mm)
Height Width Depth
20 U 235
106.6
39.37
1,000
23.62
600
23.60
600
33 U 338
153.3
62.99
1,600
23.62
600
31.50
800
38 U 407
184.6
70.87
1,800
23.62
600
31.50
800
42 U 438
198.7
78.74
2,000
23.62
600
31.50
800
47 U 473
214.5
86.61
2,200
23.62
600
31.50
800

Components—RMS
Item Weight Height
(lb) (kg) (in.) (mm)
Bragg grating interrogator 6.0 2.7
Optical subassembly 6 gauges 25.0 11.5 4.00 102
Monitor 18.5 8.4 0.67 17
Keyboard 13.5 6.0 0.50 13
RMS computer 31.0 14.0 2.00 51
Fan 4.0 1.8 2.00 51
UPS 48.0 21.6 2.00 51
Line conditioner 46.0 21.0 3.00 76
Network hub 4.5 2.1 1.00 25
Snap server 19.6 8.9 1.00 25
Rheos™ flow system 134.0 65.0 14.00 356
DTS system 37.0 17.0 7.00 178

Components—RMS-MR
Item Weight Height
(lb) (kg) (in.) (mm)
Bragg grating transmitter/receiver 6.0 2.7 4.00 102
Bragg grating receiver 0.9 0.4 - -
Monitor 18.5 8.4 0.67 17
Keyboard 13.5 6.0 0.50 13
RMS computer 31.0 14.0 2.00 51
Fan 4.0 1.8 2.00 51
UPS 48.0 21.6 2.00 51
Line conditioner 46.0 21.0 3.00 76
Network hub 4.5 2.1 1.00 25
Snap server 19.6 8.9 1.00 25
Rheos™ flow system 134.0 65.0 14.00 356
DTS system 37.0 17.0 7.00 178

Model RMS RMS-MR
General Specifications  
Number of P/T gauges monitoring capability* 18 24
Number of flowmeters supported 8/Rheos™ module
Number of DTS channels supported 9 or 18/DTS switch
Update rate selectable range 1 sec to no limit
Storage capacity >2 yr
Storage capacity with NAS option Typically 5 yr
Units of measure (selectable) Metric, Imperial, oilfield

Output Options
MODBUS, serial 232, 422, 485, and TCP/IP ASCII, RTU, master or slave
Simple serial 232, 422, 485 ASCII
OPC 2.0 data access standard Client and server
Profibus Optional
Data files by LAN or WAN Flat-file ASCII, LAS format for DTS
Web-enabled data visualization and transfer Optional
Direct SQL database access ODBC Driver

Electrical Power Specifications
Voltage 110 nominal 90 to 135 V AC, 57 to 63 Hz
Voltage 220 nominal 180 to 255 V AC, 47 to 53 Hz
Maximum current 110 5.0 amp
Maximum current 220 2.5 amp
CE low-voltage directive 73/23/EEC compliant IEC 60204-1

Environmental Specifications
Operating temperature range (°F/°C) 41° to 104°
5° to 40°
Shipping and storage temperature range (°F/°C) –104° to 185°
–40° to +85°
Thermal shock <18°F/hr
<10°C/hr
Relative humidity, non-condensing, operating range 10 to 80%
Relative humidity, non-condensing, shipping and storage range 0 to 95%
CE electromagnetic compatibility 89/336/EEC compliant EN 61000-3-2, 3-3 EN 61326-1
Operational vibration 5 to 100 Hz, 0.1 g, 90 min/axis
Transportation vibration 3.0 grms, random and sine

* 20,000-PSI (1,379-bar) P/T gauge

Options

Accessories
Line conditioner Universal
UPS 110 or 220
Profibus Interface card
Cabinet Standard sizes, custom available
Network-attached storage 240 GB Quantum Snap 4100
System clock enhancements Clock card or GPS

Configurations
Additional Component Applications
Pressure/temperature gauge Provides accurate temperature and pressure readings with no measurable drift
Distributed temperature sensor (permanent installation) Provides continuous monitoring
Distributed temperature sensor (provided as a logging service) Enables characterization of well performance
Single-phase and multiphase flowmeter Delivers accurate measurement of downhole oil, gas, and water flow rates on demand
Array temperature sensor Provides stable, high-resolution distributed temperature readings along areas of interest in the wellbore

 

Overview
Specifications
Diagram

© 2010 Weatherford International Ltd.