SEARCH     
 

Specifications of the Red Eye® 2G Water-Cut Meter

Power 10 to 30 Vdc, 8 W
Wetted parts 316 L SS or Hastelloy C 276 with sapphire windows
Operating temperature 32° to 302°F (0° to 150°C) (standard) process fluid
  -40° to 149°F (-40° to 65°C) (standard) ambient temp
Operating pressure Equal to carbon steel ANSI pressure rating
Process connection 1 in. (2.54 cm.) NPT for pipe sizes 2 to 10 in. (5.08 to 25.4 cm.)
  1.5 in. (3.81 cm.) RF flange ANSI 600 for pipe sizes 2 to 24 in. (5.08 to 60.96 cm.)
  1.5 in. (3.81 cm.) RF flange ANSI 900/1500 for pipe sizes 2 to 24 in. (5.08 to 60.96 cm.)
  2 in. (5.08 cm.) RTJ flange ANSI 900/1500 for pipe sizes 3 to 8 in. (7.62 to 20.32 cm.)
Sour service NACE MR0175/ISO 15156
Accuracy ±2% water cut
Communication ports RS-232 and RS-485
Flowmeter inputs Pulse or 4 to 20 mA
Display 2-line, 16-character vacuum fluorescent display (LCD available)
Output 4 to 20 mA water cut
Communications Modbus RTU (standard)
Hazardous area classification Factory Mutual Approvals Project I.D. 3022805 XP Class I, Division 1, Groups C & D, T3C, Ta=+85°C, CSA
  Sira Certification Services Certificate SIRA 05ATEX1138 EEx’d IIB T3 Ta=+85°C, IPX5
  Canadian Standards Association Certificate Number 1675737, Class I, Division 1, Groups C & D, T3C, Ta=+85°C, Type 4
  Serial Production Gosstandart of Russia Certificate of Conformity
  Gosstandart of Russia Explosion-proof Certificate
Hot tap A hot tap version of the Red Eye 2G water-cut meter is available, contact the factory
for details
© 2011 Weatherford International Ltd.