SEARCH     
 

Specifications of the ePAC™ II Variable Speed Drive for Progressing Cavity Pumping

Electrical Input Supply
Three-phase voltage 230, 380, 480 Vac (+10% to 15%)
Three-phase frequency 50 to 60 Hz (±5%)
Single-phase voltage 230, 480 Vac (±10% to 15%)
Single-phase frequency 50 to 60 Hz (±5%)

Electrical Power Factor
Overall 1.00 displacement power factor
0.94 overall power factor at all speeds

Electrical Output Rating
Voltage Zero to input voltage, three-phase
Frequency Zero to 120 Hz flux vector control
Zero to 300 Hz variable frequency control
Switching frequency Programmable, 2 to 15 kHz varies with Hp
Overload current 110 to 120% of rated for one minute (normal duty)

Electrical Conversion
Rectifier unit Six-diode, three-phase (six-pulse) full wave bridge below 40 Hp
Diode-SCR (12-pulse) full-wave bridge for 40 Hp and above
Inverter unit Six-IGBT, four-quadrant, trap or sine wave output

Environmental
Operating temperature -40° to 122°F (-40° to 40°C)
Storage temperature -4° to 140°F (-20° to 60°C)
Relative humidity 5% to 95%, non condensing

Inputs and Outputs
Analog inputs Three 12-bit analog inputs: one 4 to 20 mA, two 0 to 10 Vdc
Pulse input 0 to 32 kHz (flow volume configurable)
Analog outputs Two 12-bit analog outputs (4 to 20 mA)
Pulse outputs 0 to 32 kHz
Digital inputs Eight digital inputs (requires sink of 1 mA to common)
Outputs Three programmable relay outputs (1 A @ 250 Vac)
One fault contact

Serial Communications
Modbus port EIA RS-232 and RS-422/485, 1200 to 19200 baud

Enclosure
UL listed package Type 3R
  Engineered for all weather conditions
  Door interlocked breaker main disconnect
  Front mounted keypad and controls in secondary door
  Control transformer
  Panel mount enclosure (sizes one to three)
  Floor mount enclosure (sizes four and five)

Optional
  24 Vdc power supply for external analog signals
  Communication (Ethernet)
  Inlet line reactor
  IEEE-519 rated inlet harmonic package
  Long lead filter (DV/DT)

Dimensional Data
Encl. Size HP 460V HP 380V Max
Amps
Height
in.
Width
in.
Depth
in.
Weight
lbs.
1 5-30 5-25 40 36 24 20 100
2 40-50 40 67 48 24 21 180
3 60-100 50-75 125 48 30 23 210
4 125-150 100-125 180 72* 36 24 450

*Enclosure is 60 inches (175.26 cm.) high with 12 inch (30.48 cm.) floor mount stand